x

Air Shower Room

Air Shower Room
Air Shower Room
Air Shower Room
Air Shower Room
Air Shower Room
Air Shower Room
Air Shower Room
Air Shower Room
Air Shower Room
Air Shower Room

Air Shower Room

Product Introduction:

The Air Shower Room is a versatile local purification device installed at the transition point between clean and non-clean areas. Before personnel or goods enter a controlled environment, high-velocity clean air is blown through adjustable nozzles to dislodge and remove dust particles clinging to clothing, footwear, and material surfaces — effectively preventing contamination sources from entering the clean zone. Air showers are widely used in food processing facilities, pharmaceutical plants, hospitals, laboratories, electronics manufacturing, and packaging/printing environments where strict hygiene and particulate control are required.


(16) Reviews

PRODUCT DETAILS

Key Highlights

Highlight

Description

Optimized Air Duct Design

Internal duct engineered for maximum outlet air velocity and even distribution

Adjustable Shower Time

Digital display with adjustable shower duration — flexible for different protocols

Internal Air Circulation

Clean air recirculates within the chamber — maintains consistent filtration performance

Two-Stage Filtration

Pre-filter + HEPA filter system for reliable multi-level particulate removal

Intelligent Control

Manual and infrared induction modes to suit different facility requirements

304 Stainless Steel Construction

Full SS304 body — corrosion-resistant, durable, and easy to clean

 

Working Principle

Person/goods enter air shower → Doors close automatically

    ↓

Ambient air passes through pre-filter and HEPA filter

    ↓

Dedicated fan pressurizes clean air into static pressure box

    ↓

High-speed clean airflow ejected through rotatable nozzles

    ↓

Dust particles on clothing and goods surfaces blown off effectively

    ↓

Contaminated air recirculates through filters for continuous cleaning

    ↓

Shower cycle completes → Exit door opens → Personnel/goods enter clean area

 

Application Scenarios

Industry

Application

Food Processing

Personnel hygiene checkpoint before entering clean production zones — prevents cross-contamination

Pharmaceutical

GMP-compliant personnel and material decontamination at cleanroom access points

Electronics Manufacturing

Dust-free entry protection for semiconductor assembly, PCB production, and precision component areas

Laboratories

Contamination prevention at cleanroom and biosafety lab entrances

Packaging & Printing

Clean entry control for hygienic packaging and printing environments

Hospitals & Healthcare

Sterile area access control for operating rooms, clean wards, and pharmaceutical preparation rooms

 

Model Specifications

Manual Door Models

Parameter

HE-ASSD/1

HE-ASSD/2

HE-ASSD/3

Type

Manual Door

Manual Door

Manual Door

External Dimensions (mm)

1000 × 1400 × 2100

1500 × 1400 × 2100

2000 × 1400 × 2100

Nozzle Count

20

24

32

Material

304 Stainless Steel

304 Stainless Steel

304 Stainless Steel

Voltage

380V / 50Hz (Customizable)

380V / 50Hz (Customizable)

380V / 50Hz (Customizable)

Control

Intelligent

Intelligent

Intelligent

Shower Coverage

Three-sided

Three-sided

Three-sided

Infrared Induction Models

Parameter

HE-ASGY/1

HE-ASGY/2

HE-ASGY/3

Type

Infrared Induction

Infrared Induction

Infrared Induction

External Dimensions (mm)

1200 × 1700 × 2250

2000 × 1700 × 2250

3000 × 1700 × 2250

Nozzle Count

20

40

60

Material

304 Stainless Steel

304 Stainless Steel

304 Stainless Steel

Voltage

380V / 50Hz (Customizable)

380V / 50Hz (Customizable)

380V / 50Hz (Customizable)

Control

Infrared Sensing

Infrared Sensing

Infrared Sensing

Shower Coverage

Three-sided

Three-sided

Three-sided

Custom sizes, nozzle configurations, and filtration grades are available upon request.

 

FAQ

What is an air shower used for?

An air shower is installed at the entrance of cleanrooms and controlled environments to remove dust and particles from personnel and goods before they enter. It serves as a critical contamination barrier, maintaining the cleanliness level of the controlled zone.


How does an air shower work?

Ambient air is drawn through a pre-filter and HEPA filter, then pressurized by a dedicated fan into a static pressure box. The filtered clean air is ejected through adjustable nozzles at high velocity, dislodging particles from clothing and surfaces. Contaminated air is recirculated back through the filtration system for continuous cleaning.


What is the difference between manual and infrared induction air showers?

Manual air showers require personnel to press a button to start the shower cycle, suitable for general-purpose facilities. Infrared induction models activate automatically when a person enters, providing touchless operation for environments requiring stricter hygiene protocols such as pharmaceutical or food processing plants.


Can air showers be customized?

Yes. Dimensions, nozzle count, filtration grade, control mode, and shower duration can be configured to meet specific cleanroom requirements. Custom designs are available for unique facility layouts and specialized applications.